Insulation Panel Specifications
PANEL SPANS
The panels spans indicated in the table have been calulated by our engineers after a extensive panel testing programme.
Allowable spans are based on the following applied loads and deflection criteria as set out in NZS 4203:1992
Walls
0.71 kPa max wind pressure
Ceiling 0.25 kPa live load or 1kN point load
Roof
-0.84 kPa max wind pressure outwards
FIRE PERFORMANCE
Panels have been tested to the Early Fire Hazard Properties Standard AS41530 Part 3 - 1976 giving the following results.
Ignitability
Index (0-20) 0
Spread of Flame
Index (0-20) 0
Heat Evolved Index
(0-10) 0
Smoke Developed Index (0-10) 0
PANEL LENGTHS & THICKNESS
Standard styrolock thicknesses are 50, 75, 100, 125, 150, 175, 200, 225, 250, 275, 300mm
Standard
styroroof thicknesses are 50, 75, 100, 125, 150, 175, 200, 225mm
The continuous production method permits an infinite range
of panel lengths. Maximium length is only limited by handling and transportation considerations. Lengths greater than
16m are not uncommon and in excess of 26m have been transported throughout the North Island.
PANEL CORES
Self extingishing expanded polystyrene core
SURFACE FINISHES
Standard surface finish is NZ Steel CP finish. For more servere environemnts NZ Steel Maxx offers a higher level
of protection.